Independent educational resource — not affiliated with ASTM International.Purchase the official standard

Drawing and purchase-order control

ASTM A513 tolerances

Tolerance depends on type, shape, size, wall, length, condition, and the characteristic being controlled. Use the official edition for normative limits.

Edition ASTM A513/A513M-25Succession MFG editorial teamUpdated
On this page

The short answer

A513 tolerances are organized by manufacturing type, shape, and size range — there is no single tolerance for the specification. As-welded routes carry broader limits than drawn routes; squares and rectangles carry characteristics rounds do not (corner radii, squareness, twist). The normative limits are in the purchased standard, and producers may hold tighter negotiated limits than the standard requires.

The practical skill is not memorizing tables — it is identifying which characteristics your part actually needs controlled, then stating them so the producer can quote against reality.

Define the controlled characteristics

Identify outside dimension, inside dimension where applicable, wall, length, straightness, squareness, corner radii, twist, and end condition according to the product shape and part function.

For round tube destined for machining, the OD/ID relationship and wall concentricity usually dominate. For welded frames, straightness and twist usually dominate. Specify what the part cares about; accept standard limits for what it does not.

Resolve drawing conflicts

A blanket standard note can conflict with title-block or feature tolerances. Establish precedence and confirm exceptional requirements with the producer before order acceptance.

A drawing that states “ASTM A513 Type 5” and simultaneously dimensions the OD with a tighter title-block tolerance has created a conflict the receiving inspector will discover at the worst time. Decide which governs, and write it down.

Measurement matters

Agree on where and how characteristics are measured: distance from tube ends, orientation relative to the weld, ovality interpretation for rounds, and flat-to-flat versus corner measurements for shapes. Disagreements about method masquerade as disagreements about conformance.

The most common tolerance dispute we see is not about the product at all: the producer measured mid-length with a micrometer averaging across the weld, and the receiving inspector measured near a cut end with calipers at one orientation. Both read honestly; the numbers disagree. Method agreement before the first shipment prevents this entire category of rejection.

Line diagram of a round tube showing zones to avoid near cut ends, an OD measurement location at mid-length, an overall length dimension, and a cross-section detail indicating wall measurement at four points around the circumference and the weld seam orientation
Agree on measurement locations before the first shipment: away from cut ends, at stated positions, with weld orientation recorded.

How A513 organizes tolerance thinking

Without reproducing controlled tables, the structure is worth understanding: tolerances in the standard scale with manufacturing type (as-welded routes carry broader limits than drawn routes), with size range (larger sections generally carry larger absolute limits), and with shape (rounds, squares, and rectangles each have their own characteristic set). Supplementary and negotiated requirements can tighten any of these where the producer agrees.

This structure is why copying a single tolerance number from a forum or a competitor's uncontrolled table is dangerous: the number may be real, but for a different type, size band, or edition than your order.

OD, ID, or wall: pick what governs

For a tube, outside diameter, inside diameter, and wall thickness are geometrically linked — a producer cannot hold all three to their tightest simultaneously. The standard's convention and industry practice is that the buyer identifies which dimensions govern and which float.

For machined parts that pilot on the OD, let OD and wall govern and accept the resulting ID. For parts that slide over a shaft or seal on the bore, consider ordering to ID and wall — a conversation DOM producers have daily. Stating all three with tight limits does not get you a better tube; it gets you a quote query, a price adder, or a silent producer decision about which one to ignore.

Choosing governing dimensions by part function
Part functionGoverning dimensionsFloating dimensionPractical implication
Machined on OD (pilots, press fits)OD + wallIDOrder to OD/wall; stock allowance on ID
Slides or seals on boreID + wallODDiscuss ID-governed ordering with a DOM producer
Welded frame memberOD + straightnessID, wall (within standard)Standard limits usually suffice
Formed or bent componentWall + ODIDWall consistency dominates bend quality

Sources and limitations

These sources inform the qualitative guidance on this page. This publication does not reproduce their text, tables, numerical settings, or acceptance criteria. Normative requirements come only from the purchased current edition of the governing standard and your supplier agreement.

Related reading

ASTM A513 Tolerances: How to Specify Them